PROPERTIES
Electrical Properties
Value
Test Conditions
Test Method
Comparative Tracking Index
IEC 60112
Surface Resistivity
IEC 60093
Volume Resistivity
IEC 60093
Flammability Properties
Value
Test Conditions
Test Method
Flame rating (UL 94)
ISO 1210
Impact Properties
Value
Test Conditions
Test Method
Charpy Impact Strength
ISO 179/1eU
Charpy Impact Strength
ISO 179/1eU
Charpy Notched Impact Strength
ISO 179/1eA 2
Charpy Notched Impact Strength
ISO 179/1eA
Mechanical Properties
Value
Test Conditions
Test Method
Elongation at Break
ISO 527-2
Stress at Break
ISO 527-2
Tensile Modulus
ISO 527-2 2
Physical Properties
Value
Test Conditions
Test Method
Molding Shrinkage
ISO 294-4
Molding Shrinkage
ISO 294-4
Water Absorption
ISO 62
Thermal Properties
Value
Test Conditions
Test Method
Coefficient of Linear Thermal Expansion
ISO 11359-1/-2
Coefficient of Linear Thermal Expansion
ISO 11359-1/-2
Heat Deflection Temperature Under Load (HDT)
ISO 75-2 2
Heat Deflection Temperature Under Load (HDT)
ISO 75-2 2
Max. Continuous Use Temperature
ISO 2578
Max. Continuous Use Temperature
ISO 2578
Melting Temperature (Melting Point)
ISO 11357-3
CONVERSION MODE & PROCESSING GUIDELINES
Conversion Mode
Injection molding - thermoplastics
Injection - Dew point of the Dryer
-25 °C
Injection - Drying Temperature
< 80 °C
Injection - Drying Time
4 - 12 hr
Injection - Dynamic Pressure
50 - 100 bar
Injection - Flange Temperature
40 - 60 °C
Injection - Hold on Pressure
300 - 800 bar
Injection - Nozzle Temperature
265 °C
Injection - Processing (Melt) Temp
260 - 290 °C
Injection - Screw compression ratio
2 - 2.5 D
Injection - Screw length
18 - 22 D
Injection - Screw speed
0.1 - 0.3 m/s
Injection - Vaccum Oven Temperature
< 100 °C
Injection - Vaccum Oven Time
4 - 12 hr
Injection - Vent Depth
< 0.01 mm
Injection - Vent groove
2 - 5 mm
Injection - Vent Shoulder width
1.5 - 2 mm
Injection - Zone 1 Temperature
260 °C
Injection - Zone 2 Temperature
265 °C
Injection - Zone 3 Temperature
270 °C
Injection speed: medium - high
Mold Shrinkage is in accordance with ISO 294-4 and measured at 60x60x2; 300 °C / MT 80°C; 600 bar
Gate Diameter :0.8 x thickest wall section of the injection molding part
Runner Diameter: 1.4 x thickest wall section of the injection molding part (but minimum 4 mm)
Clamping Force: 7.5 kN1 x projected area (cm2) Wear protected, universal screws with shut-off nozzles are recommended (3 zones).
Shot volume of injection unit = 0.5 - 0.8 x (max. shot volume of injection unit)